Siemens SINUMERIK Operate: Ethernet DNC Settings

How to Configure Siemens SINUMERIK Operate Controls for DNC

Siemens : Ethernet DNC Settings

Instructions on Configuring Siemens SINUMERIK Operate Controls for DNC

Configuring at the Controller:

  1. Switch to SINUMERIK Operate

  2. Select Commissioning

  3. Select HMI

  4. Select Log. Drive

  5. Select a free softkey slot for the Program Manager (e.g., Drive 5)

  6. Press the "Change" softkey on the right

  7. In the settings field, configure as follows:
    Type: FTP
    Computer name: (IP address of the DNC/Edge computer)
    User name: (DNC username, case sensitive)
    Password: (to be discussed with the customer for a level of security)

  8. Confirm the settings are applied to the softkey
    ​

  9. Back out of this menu to return to the main screen

Machine should now be configured for DNC